No. |
Test item
(Test at normal temperature 25±2ºC and relative humidity≤90%) |
Criterion |
1 |
Communication Interface |
SMBus |
2 |
Capacity |
Designing battery capacity(PCM) |
40Ah |
Max capacity(Battery pack) |
320Ah |
Min capacity(Battery pack) |
500mAh |
External capacity Indication |
LED,LCD |
Compensated End-of-Discharge Voltage |
CEDV |
3 |
Voltage |
Charging voltage |
DC: 14.8V CC/CV(3.7V/1 Cell) |
Cell-balance detection voltage(Charge balance) |
80mV |
Cell-balance release voltage |
40mV |
4 |
Current |
Balance current for single cell |
100R |
Normal operating-mode current(Gas Gauge IC) |
500 uA |
SLEEP operating-mode current(Gas Gauge IC) |
100uA |
FULL SLEEP operating-mode current(Gas Gauge IC) |
10 uA |
Maximal continuous charging current |
15A(Max) |
Maximal continuous discharging current |
15A(Max) |
5 |
Over charge Protection |
Over charge detection voltage |
3.80±0.05V |
Over charge detection delay time |
2S |
Over charge release voltage |
3.55±0.05V |
6 |
Over discharge protection |
Over discharge detection voltage |
2.00±0.05V |
Over discharge detection delay time |
2S |
Over discharge release voltage |
2.7±0.05V |
7 |
Over current protection |
Over current detection voltage |
0.2±0.015V |
Over current detection current |
40±5A(adjustable) |
Detection delay time |
5~20ms |
Release condition |
Cut load |
8 |
Short protection |
Detection condition |
Exterior short circuit |
Detection delay time |
200-800us |
Release condition |
Cut load |
9 |
Resistance |
Protection circuitry(MOSFET) |
≤40mΩ |
10 |
Temperature |
Operating Temperature Range |
-40~+85ºC |
Storage Temperature Range |
-40~+125ºC |
Dimension |
L102*W50*5mm |
B+:Battery+ |
|
B-:Battery- |
SD:SMBus data line |
SC:SMBus clock line |
P+:Charge+/discharge+ |
P-:Charge-/discharge- |