Customization: | Available |
---|---|
Metal Coating: | Copper |
Mode of Production: | SMT |
Still deciding? Get samples of US$ 10/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
No. | Test item (Test at normal temperature 25±2ºC and relative humidity≤90%) |
Criterion | |
1 | Voltage | Charging voltage(4S) | DC:16.8V CC/CV(4.2V/1Cell) |
2 | Capacity | Designing battery capacity | 3000mAh |
Max capacity(Battery pack) | 150Ah | ||
3 | Current | Current consumption(Firmware running) | <600uA |
Current consumption(Sleep Mode) | <200uA | ||
Maximal continuous charging current | 10A(Max) | ||
Maximal continuous discharging current | 10A(Max) | ||
4 | Over Current (1st Level Safety) |
Over charge detection current | 6500mA |
Detection delay time | 2s | ||
Over discharge detection current | 12000mA | ||
Detection delay time | 2s | ||
5 | Over Current (2nd level safty) |
Over charge detection current | 8000mA |
Detection delay time | 1s | ||
Over discharge detection current | 15000 | ||
Detection delay time | 1s | ||
Release delay time | 8s | ||
6 | Over charge Protection (for single cell) |
Over charge detection voltage | 4.3±0.025V |
Over charge detection delay time | 2S | ||
Over charge release voltage | 3.9±0.05V | ||
Over charge detection release delay time | 20s | ||
7 | Over discharge protection (for single cell) |
Over discharge detection voltage | 2.5±0.05V |
Over discharge detection delay time | 2s | ||
Over discharge release voltage | 3.0±0.05V | ||
8 | Over charge Protection(Pack) 1st Level Safety |
Over charge detection voltage | 17.5V |
Over charge detection delay time | 2s | ||
Over charge release voltage | 16V | ||
9 | Over charge Protection (Pack) 2nd Level Safety |
Over charge detection voltage | 18V |
10 | Over discharge protection(Pack) | Over discharge detection voltage | 11V |
Over discharge detection delay time | 2s | ||
Over discharge release voltage | 12V | ||
Over discharge detection release delay time | 0s | ||
11 | Short protection | Detection condition | Exterior short circuit |
Detection delay time | 200-500us | ||
Release condition | Cut load | ||
12 | Resistance | Protection circuitry(B- to P- and B+ to P+) | ≤100mΩ |
13 | Over temperature protection (1st Level Safety) |
Charge | 55ºC±5ºC |
Charge delay time | 2s | ||
Over temperature charge recovery | 50ºC±5ºC | ||
Discharge | 60ºC±5ºC | ||
Discharge delay time | 2s | ||
Discharge delay recovery time | 55ºC±5ºC | ||
14 | Over temperature protection (2nd Level Safety) |
Charge | 65ºC±5ºC |
Charge delay time | 0s | ||
Discharge | 75ºC±5ºC | ||
Discharge delay time | 0s | ||
15 | Temperature | Operating Temperature Range | -20~+85ºC |
Storage Temperature Range | -20~+125ºC | ||
Dimension | L90*W45*T6mm |